Korayat Mosque, Korayat Saudi Arabia

Mosque complex with integrated climate and utility systems with a cooling load of 7000 TR and electrical load of 6 MVA.
The climate control systems:
- Central chiller plant to cool covered area.
- Desert cooler system to condition open courtyard.
- Direct expansion for auxiliary zones.
- Heat pump to pre-cool and heat water supply.
The electrical system consists of: Power supply station, low current system, and emergency power supply.
Scope of works
Design of MEP works.
Design of HVAC, lighting and power supply systems.

Hail mosque, Saudi Arabia

Mosque complex with integrated climate and utility systems with a cooling load of 7000 TR and electrical load of 6 MVA.
The climate control systems:
- Central chiller plant to cool covered area.
- Desert cooler system to condition open courtyard.
- Direct expansion for auxiliary zones.
- Heat pump to pre-cool and heat water supply.
The electrical system consists of: Power supply station, low current system, and emergency power supply.
Scope of works
Design of MEP works.
Design of HVAC, lighting and power supply systems.

Al-Aref Bel ALLAH Sidi Abo Al Hassan Mosque, Aswan, Egypt

Mosque with integrated climate and electrical systems with a cooling load of 7000 TR and electrical load 6 MVA.
The climate systems include:
- Desert cooler system to cool the open areas.
- Direct expansion to condition enclosed and auxiliary zones.
- Domestic water to pre-cool and heat water supply.
The electrical system comprises: Power supply station, low current systems, and emergency backup power.
Scope of works
Design of MEP works.
Design of HVAC, lighting and power supply systems.

Tajmahal Mosque, Porto Sharm, Egypt

Mosque emphasizes efficient design with a cooling capacity of 60 TR and electrical load 6 MVA.
The mosque uses the direct expansion system to cool enclosed areas and the domestic water system.
Its electrical system includes: Power supply station, low current system, and emergency power supply.
Scope of works
Design of MEP works.
Design of HVAC system.

Sakaka mosque

Mosque complex with integrated climate and utility systems with a cooling load of 7000 TR and electrical load of 6 MVA.
The climate control systems:
- Central chiller plant to cool covered area.
- Desert cooler system to condition open courtyard.
- Direct expansion for auxiliary zones.
- Heat pump to pre-cool and heat water supply.
The electrical system consists of: Power supply station, low current system, and emergency power supply.
Scope of works
Design of MEP works.
Design of HVAC, lighting and power supply systems.